Search results for "Continuous glucose monitoring"

showing 10 items of 18 documents

Professional continuous glucose monitoring in subjects with type 1 diabetes: retrospective hypoglycemia detection.

2013

Background: An important task in diabetes management is detection of hypoglycemia. Professional continuous glucose monitoring (CGM), which produces a glucose reading every 5 min, is a powerful tool for retrospective identification of unrecognized hypoglycemia. Unfortunately, CGM devices tend to be inaccurate, especially in the hypoglycemic range, which limits their applicability for hypoglycemia detection. The objective of this study was to develop an automated pattern recognition algorithm to detect hypoglycemic events in retrospective, professional CGM. Method: Continuous glucose monitoring and plasma glucose (PG) readings were obtained from 17 data sets of 10 type 1 diabetes patients und…

AdultBlood GlucoseMalemedicine.medical_specialtyendocrine system diseasesEndocrinology Diabetes and MetabolismBiomedical EngineeringBioengineeringHypoglycemiaSensitivity and SpecificityAutomationDiabetes managementBlood Glucose Self-MonitoringDiabetes mellitusInternal MedicineMedicineHumansIntensive care medicineGlycemicMonitoring PhysiologicRetrospective StudiesType 1 diabetesbusiness.industryContinuous glucose monitoringBlood Glucose Self-Monitoringnutritional and metabolic diseasesRetrospective cohort studyMiddle Agedmedicine.diseaseHypoglycemiaDiabetes Mellitus Type 1Original ArticlebusinessAlgorithmsJournal of diabetes science and technology
researchProduct

Comment on Umpierrez and Klonoff. Diabetes Technology Update: Use of Insulin Pumps and Continuous Glucose Monitoring in the Hospital. Diabetes Care 2…

2019

We applaud Umpierrez and Klonoff (1) for reviewing the evidence on the application of insulin pump therapy (continuous subcutaneous glucose infusion [CSII]) and continuous glucose monitoring in inpatient settings. However, we missed a dedicated section about the patients’ perspective and experiences concerning insulin pump use in hospitals. In a qualitative survey conducted in Germany, elderly patients with type 1 diabetes (≥65 years, n = 136) and health care professionals (HCP, n = 96) were asked about their wishes, concerns, and needs related to CSII (2). The 290 responses (165 patients; 125 HCPs) were classified into three categories. First were positive experiences (patients n = 17; HCP…

Advanced and Specialized NursingInsulin pumpmedicine.medical_specialtyType 1 diabetesContinuous glucose monitoringbusiness.industryEndocrinology Diabetes and MetabolismInsulinmedicine.medical_treatmentMEDLINE030209 endocrinology & metabolismmedicine.disease03 medical and health sciences0302 clinical medicineDiabetes mellitusBlood Glucose Self-MonitoringEmergency medicineHealth careInternal Medicinemedicine030212 general & internal medicinebusinessDiabetes Care
researchProduct

Patient-Reported Outcomes and Continuous Glucose Monitoring: Can We Do Better With Artificial Pancreas Devices?

2015

Patient-reported outcomes (PROs) assess a person’s experience, feelings, and thoughts about both their condition and its treatment. PROs are able to contribute to a benefit assessment of new medical products by introducing the patients’ subjective evaluation of medical products into the evaluation process. Thus, PROs are also the cornerstone of medical product development for understanding patients’ perceptions on medical products and/or its benefit assessment. In the past 15 years, PROs were also evaluated in most clinical trials performed with continuous glucose monitoring systems. However, in its recent evaluation of such trials, the German Institute for Quality and Efficiency in Health …

Advanced and Specialized Nursingmedicine.medical_specialtyContinuous glucose monitoringbusiness.industryEndocrinology Diabetes and Metabolismmedia_common.quotation_subjecteducationArtificial pancreashumanitiesClinical trialFeelingMedical productHealth careInternal MedicineMedicineQuality (business)businessIntensive care medicinemedia_commonDiabetes Care
researchProduct

Frequent and severe hypoglycaemia detected with continuous glucose monitoring in older institutionalised patients with diabetes.

2021

AbstractBackgroundLittle is known about the prevalence of hypoglycaemia in older people with diabetes. However, the HbA1c goal is ≥8% for institutionalised patients with treatments that can cause hypoglycaemia.PurposeWe aimed to assess the prevalence of hypoglycaemia with continuous glucose monitoring and to evaluate the link with HbA1C in older institutionalised patients with diabetes taking potentially hypoglycaemia-inducing drugs.DesignProspective, multicentre study carried out in six geriatric care centres in the Côte d’Or region of France between January 2019 and July 2020.Settings, subjects and methodsA FreeStyle Libre Pro® (FSLP) was worn for up to 14 days in blinded mode in 42 patie…

Blood GlucoseAgingPediatricsmedicine.medical_specialtyendocrine system diseasesPopulation030209 endocrinology & metabolismHypoglycemia03 medical and health sciences0302 clinical medicineDiabetes mellitusmedicineHumansHypoglycemic AgentsIn patient030212 general & internal medicineProspective StudiesCognitive impairmenteducationAgededucation.field_of_studyHigh prevalenceContinuous glucose monitoringbusiness.industryBlood Glucose Self-Monitoringnutritional and metabolic diseasesGeneral Medicinemedicine.diseaseHypoglycemiaIncreased riskDiabetes Mellitus Type 2Geriatrics and GerontologybusinessAge and ageing
researchProduct

Chronic consumption of an inositol-enriched carob extract improves postprandial glycaemia and insulin sensitivity in healthy subjects: A randomized c…

2016

Background & aims: Inositols are thought to be mediators of the insulin signalling pathway. We assessed the effects of inositols on glycaemic control in fasting and postprandial states and evaluated lipoprotein profile and LDL particle size in healthy population. Methods: A 12-week double-blind clinical trial was performed with forty healthy subjects administered either an inositol-enriched beverage (IEB) -containing 2.23 g of inositols in 250 ml- or a sucrose-sweetened beverage (SB) twice a day. Anthropometric measurements, fasting glucose levels, insulin and HOMA-IR index, lipoprotein profile and postprandial glucose concentrations (measured using the continuous glucose monitoring system …

Blood GlucoseMaleApolipoprotein Bmedicine.medical_treatment030204 cardiovascular system & hematologyCritical Care and Intensive Care Medicinelaw.inventionchemistry.chemical_compound0302 clinical medicineRandomized controlled triallawContinuous glucose monitoring systemHealthy subjects030212 general & internal medicineHypolipidemic AgentsNutrition and DieteticsbiologyArea under the curveFabaceaePostprandial PeriodPostprandialLDL particle sizeSeedsFemaleInositolsAdultmedicine.medical_specialtyCarob pod extractMonitoring AmbulatoryHyperlipidemias03 medical and health sciencesDouble-Blind MethodInternal medicinemedicineHumansHypoglycemic AgentsParticle SizePinitolPlant Extractsbusiness.industryPinitolInsulinMetabolismEndocrinologyLipoproteins IDLchemistrySpainFruitHyperglycemiaDietary Supplementsbiology.proteinInsulin ResistancebusinessInositolLipoproteinClinical Nutrition
researchProduct

Extensive Assessment of Blood Glucose Monitoring During Postprandial Period and Its Impact on Closed-Loop Performance.

2017

[EN] Background: Closed-loop (CL) systems aims to outperform usual treatments in blood glucose control and continuous glucose monitors (CGM) are a key component in such systems. Meals represents one of the main disturbances in blood glucose control, and postprandial period (PP) is a challenging situation for both CL system and CGM accuracy. Methods: We performed an extensive analysis of sensor¿s performance by numerical accuracy and precision during PP, as well as its influence in blood glucose control under CL therapy. Results: During PP the mean absolute relative difference (MARD) for both sensors presented lower accuracy in the hypoglycemic range (19.4 ± 12.8%) than in other ranges (12.2…

Blood GlucoseMaleTime FactorsGlucose controlEndocrinology Diabetes and MetabolismSpecial Section: Artificial Pancreas: Models Signals and Control0302 clinical medicineInsulin030212 general & internal medicineContinuous glucose monitoringAccuracymedicine.diagnostic_testContinuous glucose monitoringPostprandial periodSignal Processing Computer-AssistedMiddle AgedPostprandial PeriodINGENIERIA DE SISTEMAS Y AUTOMATICAType 1 diabetesPostprandialTreatment OutcomeClosed-loop controlCardiologyFemaleGlucose monitorsAlgorithmsAdultmedicine.medical_specialtyTransducersBiomedical Engineering030209 endocrinology & metabolismBioengineering03 medical and health sciencesInsulin Infusion SystemsPredictive Value of TestsInternal medicineInternal MedicinemedicineHumansHypoglycemic AgentsBlood glucose monitoringType 1 diabetesbusiness.industryBlood Glucose Self-MonitoringReproducibility of Resultsmedicine.diseaseHypoglycemiaEndocrinologyDiabetes Mellitus Type 1businessClosed loopBiomarkersJournal of diabetes science and technology
researchProduct

A Multiple Local Models Approach to Accuracy Improvement in Continuous Glucose Monitoring

2011

Continuous glucose monitoring (CGM) devices estimate plasma glucose (PG) from measurements in compartments alternative to blood. The accuracy of currently available CGM is yet unsatisfactory and may depend on the implemented calibration algorithms, which do not compensate adequately for the differences of glucose dynamics between the compartments. Here we propose and validate an innovative calibration algorithm for the improvement of CGM performance.CGM data from GlucoDay(®) (A. Menarini, Florence, Italy) and paired reference PG have been obtained from eight subjects without diabetes during eu-, hypo-, and hyperglycemic hyperinsulinemic clamps. A calibration algorithm based on a dynamic glo…

Blood Glucosemedicine.medical_specialtyCalibration (statistics)Endocrinology Diabetes and MetabolismMonitoring Ambulatory030209 endocrinology & metabolismBiosensing TechniquesAccuracy improvementSensitivity and Specificity01 natural sciencesGlobal model03 medical and health sciences0302 clinical medicineEndocrinologyInternal medicineBlood Glucose Self-MonitoringDiabetes MellitusmedicineHumansGlucose dynamicsPlasma glucoseContinuous glucose monitoringbusiness.industryBlood Glucose Self-Monitoring010401 analytical chemistryReproducibility of ResultsPattern recognition0104 chemical sciencesMedical Laboratory TechnologyEndocrinologyCalibration algorithmArtificial intelligencebusinessAlgorithmsDiabetes Technology & Therapeutics
researchProduct

Glycemic Variability Assessment with a 14-Day Continuous Glucose Monitoring System: When and How Long to Measure MAGE (Mean Amplitude of Glucose Excu…

2021

Mean amplitude of glucose excursion (MAGE) is considered as the “gold standard” for assessing the short-term within-day glycemic variability (GV), which is an important component of overall glycemic control. A 14-day continuous glucose monitoring system is now widely used and allows easier assessment of GV. However, it is still unknown whether MAGE, usually calculated on a 48-hour period is identical whatever the time during the 14-day lifespan of the sensor and whether a longer time period might give additional information. We evaluated in 68 patients with type 1 diabetes, MAGE during three 2-day periods (day1-day3; day6-day8; day11-day13) and during periods of 3 days and 4 days. MAGE cal…

Blood Glucosemedicine.medical_specialtyEndocrinology Diabetes and MetabolismBiomedical Engineering030209 endocrinology & metabolismBioengineering030204 cardiovascular system & hematology03 medical and health sciences0302 clinical medicineInternal medicineTechnology ReportsInternal MedicinemedicineHumansReliability (statistics)GlycemicType 1 diabetesContinuous glucose monitoringbusiness.industryBlood Glucose Self-MonitoringReproducibility of ResultsGold standard (test)Glucose excursionmedicine.diseaseGlucoseAmplitudeDiabetes Mellitus Type 2CardiologybusinessJournal of Diabetes Science and Technology
researchProduct

Psychosocial Aspects of Continuous Glucose Monitoring

2016

Continuous glucose monitoring (CGM) systems provide people with diabetes with valuable real-time information on glucose trajectories and trends, thus offering opportunities for improving diabetes self-management. Ample evidence from clinical trials underscores CGM effectiveness for biomedical outcomes including HbA1C and hypoglycemia. However, interindividual variability in CGM uptake seems to be substantial: Neither do all individuals with diabetes adopt CGM readily in their diabetes self-management, nor do all of them benefit from CGM. In this article, we focus on CGM effects on quality of life and the potential role of psychosocial patient characteristics for determining the uptake and …

Blood Glucosemedicine.medical_specialtyendocrine system diseasesEndocrinology Diabetes and MetabolismBiomedical EngineeringPatient characteristics030209 endocrinology & metabolismBioengineeringHypoglycemia03 medical and health sciences0302 clinical medicineQuality of life (healthcare)Diabetes mellitusDiabetes MellitusInternal MedicinemedicineHumans030212 general & internal medicineSpecial Section: Psychological Factors for Diabetes Technology Part IIIntensive care medicineContinuous glucose monitoringbusiness.industryBlood Glucose Self-Monitoringnutritional and metabolic diseasesmedicine.diseaseClinical diabetesClinical trialQuality of LifebusinessPsychosocialJournal of Diabetes Science and Technology
researchProduct

Ambulatory Glucose Profile Applied to Flash Glucose Monitoring in Real Life: An Expert Opinion.

2016

The clinical benefits of real time continuous glucose monitoring (rtCGM) use have been well demonstrated in both CSII- and MDI-treated individuals in large clinical trials. However, recommendations for patient use of rtCGM in everyday life situations are lacking. This article provides guidance to clinicians and patients with type 1 diabetes (T1D) in effective use of rtCGM data, including glucose rate of change (ROC) arrows, for insulin dosing adjustments and other treatment decisions. The recommendations presented here are based on our own clinical experiences as endocrinologists, our personal experiences living with T1D using rtCGM, and findings from a recent survey of T1D patients who hav…

Blood Glucosemedicine.medical_specialtymultiple daily insulin injectionstype 1 diabetesEndocrinology Diabetes and MetabolismMonitoring ambulatoryBiomedical Engineeringflash glucose monitoringrate of changeMonitoring Ambulatory030209 endocrinology & metabolismBioengineeringglucose-monitoring systemMDI03 medical and health sciencesFlash (photography)0302 clinical medicineDiabetes mellitusBlood Glucose Self-MonitoringmedicineInternal MedicineIn real lifeambulatory glucose profile; diabetes; flash glucose monitoring; glucose-monitoring systems; glycemic control030212 general & internal medicineglucose-monitoring systemsIntensive care medicineambulatory glucose profileExpert TestimonyReview Articlesdiabetesbusiness.industryMedicine (all)Blood Glucose Self-MonitoringCSIImedicine.diseaseDiabetes Mellitus Type 1GlucosediabeteExpert opinioninsulin pumpAmbulatoryglucose profileglycemic controlcontinuous glucose monitoringMedical emergencybusinessJournal of diabetes science and technology
researchProduct